Networking Architecture

Kube-DC uses Kube-OVN for Project VPCs and external-address routing, Multus for additional interfaces, and Envoy Gateway for HTTP, HTTPS, and gRPC exposure.

Quick Navigation

SectionDescription
Network TypesCloud vs Public networks
Physical LayerVLANs and provider bridges
OVN ArchitectureVPCs, subnets, routers
Service ExposureLoadBalancers, Gateway Routes
Datacenter VLAN attachmentPutting a project on a datacenter VLAN
Envoy GatewayHTTP/HTTPS/gRPC routing

External network types

Kube-DC supports two external network types. Their CIDRs, VLANs, gateways, and provider interfaces are installation-specific.

TypeDefault logical nameAddress reachabilityTypical use
Cloudext-cloudPrivate datacenter or cloud fabric; normally not internet-routable from outsideProject gateways, private EIPs, private LoadBalancer Services
Publicext-publicInternet-routable when the datacenter routes the poolPublic EIPs, FIPs, and LoadBalancer Services

A Cloud address can still provide outbound internet access through the datacenter gateway and Project SNAT. A Public address is not automatically safe or exposed: routing, firewall policy, quota, and the workload listener still apply.

Example addresses

Examples in this guide use documentation ranges such as 198.51.100.0/24 and sample private space. Replace them with the ranges configured in your Fleet overlay. They are not Kube-DC defaults.

Physical network layer

Provider networks attach Kube-OVN to datacenter Layer 2 or routed segments. Depending on the installation, a provider network can use a VLAN on a shared trunk, a dedicated interface, or an existing OVS bridge.

External provider network attachmentOptional private and public provider segments converge on a Kube-OVN ProviderNetwork. The ProviderNetwork attaches to an OVS bridge on eligible nodes, and OVS connects those segments to OVN logical routers.Cloud segmentoptional privateVLAN / routedPublic segmentoptional publicrouted poolProviderNetworkKube-OVNOVS bridgeeligible nodesbridge attachmentRoutersOVN
Provider networks bind installation-specific private or public segments to eligible-node OVS bridges; Kube-OVN owns the logical attachment and routing.

The operator must ensure that every eligible node receives the expected VLANs or routed segments. Kube-OVN and OVS own the logical attachment; do not assume a Linux VLAN subinterface with a particular name will exist.

OVN logical network

The management VPC hosts platform networking. Each Project receives a separate VPC and workload subnet.

Management and Project network isolationPods and virtual machines attach to the Project workload subnet and Project logical router inside the Project VPC. The router uses the configured cloud network for the default EIP and outbound SNAT. When configured, an optional public EIP, Floating IP, or LoadBalancer Service can use the public external network. Platform Pods and Services remain in the separate management VPC.PROJECT VPC · ISOLATED WORKLOAD NETWORKMANAGEMENT VPCWorkloadsPods + VMsProject subnetspec.cidrBlockLogical routercontrolled routingPlatform networkplatform PodsServicesCloud networkext-cloudEIP · SNATPublic networkext-publicEIP · FIP · LB
Each Project has its own VPC and creator-supplied workload subnet. Its default EIP and SNAT use the selected external network; public EIPs, FIPs, and Services are optional explicit paths.

The Project's spec.cidrBlock is required input supplied by the creator or UI; the controller does not allocate it from an external-network CIDR. The Project's immutable spec.egressNetworkType selects the external network used by its default gateway.

Policy routing for secondary external networks

When a workload uses an EIP from a different external network than its Project's default, Kube-DC programs source-based OVN logical-router policies so reply traffic returns through the matching gateway. This is required for FIPs and LoadBalancer Services on secondary provider networks.

The policy priorities are an implementation detail. Inspect the Project VPC and the owning EIP or Service status when troubleshooting; do not reproduce these routes manually.

Service exposure

Choose an exposure method by protocol and reachability:

MethodProtocolsAddress behaviorUse when
Gateway routeHTTP, HTTPS, gRPC, and supported TLS routesShares the configured Envoy Gateway listener and hostnameThe application has a hostname-based protocol and should use Gateway API routing or managed TLS
LoadBalancer ServiceTCP or UDPUses the Project default EIP or a named EIP and an OVN load balancerThe application needs a direct port or non-HTTP protocol
FIPIP protocols supported by the OVN NAT pathMaps one EIP to a VM interface or explicit internal IPA single workload needs a stable 1:1 NAT address

A Cloud address is reachable only through the configured private provider network. A Public address is internet-routable only when the datacenter routes the pool and applicable firewalls allow the traffic. The diagrams and resource status cannot establish external reachability on their own.

EIP resources

An EIp reserves an address from either the cloud or public external network:

apiVersion: kube-dc.com/v1
kind: EIp
metadata:
name: application-address
namespace: acme-production
spec:
externalNetworkType: cloud

Omitting externalNetworkType uses the platform's configured EIP default. Set it explicitly in operator examples when the network choice matters.

FIP resources

A FIp creates 1:1 NAT from an EIP to either an explicit internal address or a selected VM interface. The target retains its internal IP.

apiVersion: kube-dc.com/v1
kind: FIp
metadata:
name: application-fip
namespace: acme-production
spec:
ipAddress: 10.40.0.20
eip: application-address

Use vmTarget instead of ipAddress when the controller should resolve a KubeVirt VM interface.

LoadBalancer Services

Kube-DC's Service controller binds a type: LoadBalancer Service to an EIP and Kube-OVN programs the OVN load balancer. Select the address with one of these annotations:

  • service.nlb.kube-dc.com/bind-on-default-gw-eip: "true" uses the Project gateway EIP;
  • service.nlb.kube-dc.com/bind-on-eip: "<name>" uses a named EIP.

The controller also maintains a companion <service>-ext headless Service and Endpoints object for a stable cluster DNS name. That DNS record tracks the external IP; it does not create cross-Project routing or authorize traffic. The source Project still needs a reachable provider-network path and applicable router-policy allow rules.

Project network provisioning

When a Project is created:

  1. the creator supplies spec.cidrBlock and spec.egressNetworkType;
  2. the controller creates a VPC, workload subnet, and default NetworkAttachmentDefinition;
  3. the controller allocates the default gateway EIP and programs outbound SNAT;
  4. VPC DNS and enabled ingress/egress router policies reconcile.

Project VPC CIDRs may overlap because the VPCs are separate. Choose non-overlapping ranges when Projects may later be routed together, attached to a shared underlay, or connected to the same external network.

apiVersion: kube-dc.com/v1
kind: Project
metadata:
name: production
namespace: acme
spec:
cidrBlock: 10.40.0.0/20
egressNetworkType: cloud

A public Project additionally requires allow_public_projects and a configured public external network. Creating an arbitrary namespace does not run this workflow.

Overlay and underlay networks

The default Project network is a Kube-OVN overlay VPC. It is independent of the physical VLAN layout and supplies the Project's primary interface and default route.

An underlay attachment connects an additional workload interface to a physical broadcast domain. The physical network, address plan, and node cabling become part of the isolation boundary. The Project's VPC policies do not isolate traffic carried on that secondary underlay interface.

Attaching a Project to a datacenter VLAN

An operator declares a physical FabricSegment and allocates it to an Organization. An Organization administrator can then bind the allocation to a Project. Kube-DC publishes a generated NetworkAttachmentDefinition after the segment and eligible nodes are ready.

Attaching a Project VPC to a routed network

A Routed Network gives the whole Project VPC destination-specific reachability to approved external prefixes. Kube-DC operates redundant routing gateways and BGP; the Project's normal Internet path remains separate.

Project VPC connected to an approved remote network with BGPWorkloads in Project production use VPC 10.0.0.0/24. The Project VPC router sends approved remote destinations through two managed routing gateway replicas in active and standby mode. Those gateways exchange the Project CIDR and approved prefix 198.51.100.0/24 over eBGP with an external router or firewall. Other traffic continues through the Project's existing default gateway to the Internet. If no managed gateway has a healthy approved route, remote-destination traffic fails closed instead of falling through to the Internet path.eBGPapproved routePROJECT PRODUCTION · VPC 10.0.0.0/24KUBE-DC ROUTINGROUTED DOMAINWorkloadsPods + VMsVPC routerapproved routesdefault separateBGP pairtwo replicasactive · standbyEdge peerrouter / FWmanaged policyRemote CIDR198.51.100.0/24Default pathexisting gatewayInternetSNAT unchangedSeparate paths by destinationApproved remote destinations fail closed; other traffic keeps the default Internet path.
A whole Project VPC—not a second workload interface—reaches only operator-approved remote prefixes through redundant managed gateways. BGP remains platform-managed, while the Project's default Internet path stays unchanged.

Network security

  • A dedicated Kube-OVN VPC and workload subnet provide the primary Project network boundary.
  • Optional ingress and egress logical-router policies restrict traffic on shared cloud and public external networks.
  • Kubernetes NetworkPolicy can provide additional application-level Pod controls, but no standard Project Role grants NetworkPolicy authoring.
  • Datacenter VLAN attachments inherit the isolation and visibility of the physical segment.

See the Security model for router-policy behavior, allowlists, admission controls, and residual risk.

Envoy Gateway

Envoy Gateway provides hostname-based HTTP, HTTPS, gRPC, and supported TLS routing for Services. Fleet and the chart own the Gateway, listener addresses, routes for platform services, and certificate configuration.

Envoy Gateway request flowA client reaches the Envoy Gateway listener through DNS and a reachable provider path. Envoy matches a Gateway API hostname and route, forwards to a Kubernetes Service, and the Service sends the request to a Project workload.DNS + provider pathhostname matchClientexternalrequestEnvoy listenerHTTP · HTTPSgRPCRouteGateway APIServiceclusterserviceWorkloadProject
Envoy Gateway performs hostname-based routing only after DNS and the provider path make its listener reachable. Route, certificate, Service, and workload health remain separate checks.

A Service can request a generated route through Kube-DC's supported annotations, including service.nlb.kube-dc.com/expose-route and an optional custom route hostname. The route controller publishes status on the Service. Verify DNS, certificate readiness, Gateway route status, backend health, and external routing separately.

How the listener is reached

Envoy runs as a Deployment on the host network, one replica per node labelled kube-dc.com/ingress (required anti-affinity, so two replicas cannot share a node), and binds those nodes' :80 and :443 directly. Because the packet arrives at the node rather than being forwarded through the Service, Envoy sees the real client address — which is what per-client rate limits, source allowlists and honest audit logs depend on.

Binding privileged ports means the envoy container runs as UID 0. It keeps the rest of the generated hardening (drop: [ALL] plus NET_BIND_SERVICE, no privilege escalation, seccomp RuntimeDefault), and the shutdown-manager sidecar stays non-root without the capability. A capability alone is not sufficient here: a non-root process under NoNewPrivs never gets an added capability into its effective set, and Kubernetes exposes no way to set ambient capabilities, so a non-root Envoy starts, reports Ready, and fails to bind every listener.

Host-bind changes what a NetworkPolicy sees

Because Envoy is on the host network, everything it proxies to an upstream arrives with a node IP as its source — not a pod IP in envoy-gateway-system. A NetworkPolicy that admits Envoy with

- namespaceSelector:
matchLabels:
kubernetes.io/metadata.name: envoy-gateway-system

therefore can never match, because the CNI cannot map a node IP back to a pod namespace. The policy fails closed, and the only symptom is a 503 from whatever sits behind it.

This is not theoretical. It took a production front door's OpenBao offline for 44 hours: a managed cluster's KMS plugin could not log in, the apiserver's kms-providers readiness check failed (livez 200, readyz 500), and the tenant control plane sat NotReady while its worker VMs were Running the whole time.

Such a policy needs an address peer for the ingress nodes, which is what INGRESS_HOST_CIDR supplies:

- ipBlock:
cidr: "${INGRESS_HOST_CIDR}" # subnet carrying the ingress nodes' upstream source

There is no tidier option on this platform. NetworkPolicyPeer cannot reference nodes, and the pinned Kube-OVN version skips hostNetwork pods when building selected ports, so a podSelector on Envoy cannot work either. The alternatives are giving up hostNetwork, adding a non-hostNetwork proxy hop, or SNATing Envoy's upstreams into a controlled range.

Do not derive that CIDR from the node's LAN prefix. On at least one cluster in this fleet the recorded node CIDR is a public /26 while the management addresses are private — a derived value there would have admitted a prefix containing none of the real sources. Set it from the addresses the ingress nodes actually egress with, and let scripts/frontdoor-check.sh preflight confirm containment.

INGRESS_HOST_CIDR has no default, deliberately: it previously defaulted to 127.0.0.1/32, which is syntactically valid, passes every render and validation gate, and admits nothing.

Which address reaches those nodes is a separate, per-cluster choice — INGRESS_ADDRESS_LAYER:

LayerAddressService shape
metallb-l2 / metallb-bgp (recommended)a MetalLB VIP, announced only from a node holding a ready EnvoyLoadBalancer, loadBalancerClass: metallb, externalTrafficPolicy: Local, externalIPs cleared
nonethe ingress nodes' own addresses via wildcard DNSClusterIP retaining externalIPs

Health-gated announcement is the practical difference: on a MetalLB layer the address moves to another already-serving node during a node loss or a rolling update, so the front door stays up. On none the address belongs to one node and cannot move.

Both shapes come from two shared components (gateway-config/components/host-bind and, for a VIP, gateway-config/components/address-metallb) rather than per-cluster EnvoyProxy edits. Envoy Gateway itself does not make a private Cloud address reachable from the internet.